Comet H3061P compressed air temperature and humidity regulator with 230Vac/8A relays

Previous 9 / 144 Next

Quantity
Add Quotation


Download Files

Cometsystem_H3061P.pdf (96.76 KB)
code: H3061P
Humidistat, thermostat with two relay outputs. T+RH probe from hard anodized duralumin for compressed air up to 25 bars with 1m cable. Cable lengths 2m or 4m available optionally. Outdoor, indoor use.
 

Relative humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.

 

Included in delivery: 

  • Traceable calibration certificate
  • Quick start manual
  • Free program TSensor for configuring of the transmitter

Technical parameters Value
Output None
Measured Value Temperature + Relative Humidity
Construction Type Compressed Air Humidity up to 2.5MPa
Design Industrial
Temperature Measuring Range -30 to 105 °C
Relay Output Yes 230V
Two-State Input No
Lcd Display Yes
PoE No
Maximum switching voltage, current, power of relay output 250Vac, 8A
Audible alarm from built-in beeper - switchable
Relative humidity range 0 to 100%
Accuracy of relative humidity measurement ±2.5% relative humidity from 5 to 95% at 23°C
Accuracy of temperature output ±0.4°C from -30 to +100°C
±0.4% from reading over +100°C
Available temperature units degrees Celsius, Fahrenheit
Dew point temperature range -60 to +80 °C
Accuracy of dew point temperature output (for more details see instruction manual) ±1.5°C for dew point temperature +10°C and higher at ambient temperature +25°C
Accuracy of dew point temperature output ±2.0°C for dew point temperature 0°C at ambient temperature +25°C
Accuracy of dew point temperature output ±3.0°C for dew point temperature -10°C at ambient temperature +25°C
Accuracy of dew point temperature output ±6.0°C for dew point temperature -20°C at ambient temperature +25°C
Accuracy and range of absolute humidity output ±1.5g/m3 at ambient temperature T < 25°C
range 0 to 400 g/m3
Accuracy and range of specific humidity output ±2g/kg at ambient temperature T < 35°C
range 0 to 550 g/kg
Accuracy and range of mixing ratio output ±2g/kg at ambient temperature T < 35°C
range 0 to 995 g/kg
Accuracy and range of specific enthalpy output ±3kJ/kg at ambient temperature T < 25°C
range: 0 to 995 kJ/kg
Temperature operating range -30 to +80°C
Temperature operating range of LCD display readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C
Temperature compensation of the humidity sensor all temperature range
Filtering ability of sensor cover 0.025mm - filter with stainless steel mesh
IP protection IP65 electronics, IP40 sensors
Power 110 to 240V / 50Hz to 60Hz
Current consumption 230 VAC - max. 70 mA, 115 VAC - max. 120 mA
Mechanical connection of probe G1/2 with O-Ring
Length of the probe cable 1m, 2m or 4m optionally
Dimensions 136 x 161 x 45 mm (W x H x D), probe length 150 mm, probe diameter 18mm
Weight approximately 490g - 1m probe

Optional accessories

Description
cable for transmitter adjustment via USB port
Flow chamber for compressed air measurement up to 25 bars
Wall holder for external probes DIGIL
plastic sensor protection with stainless filter (black)
Tool for easy connection to WAGO terminals 233 for serial output transmitters
Vessel for adjustment and calibration of humidity
Humidity Standard 10%RH, set 5pcs
Humidity Standard 80%RH, set 5pcs


You have 0 items in you cart. Would you like to checkout now?
0 items