| Technical parameters | Value |
| Output | Ethernet |
| Measured Value | Temperature + Relative Humidity + Atmospheric Pressure |
| Construction Type | With T+RH Probe on Cable |
| Design | Industrial |
| Temperature Measuring | Range -30 to 80 °C |
| Relay Output | No |
| Two-State Input | No |
| Lcd Display | Yes |
| PoE | No |
| Relative humidity range | 0 to 100% |
| Accuracy of relative humidity measurement | ±2.5% relative humidity from 5 to 95% at 23°C |
| Accuracy of temperature output | ±0.6°C |
| Maximum measuring atmospheric pressure range | 600 to 1100hPa |
| Accuracy of atmospheric pressure | ±1.3hPa at 23°C |
| Resolution | 0.1°C, 0.1%RH, 0.1hPa |
| Measuring interval | 2s |
| Available temperature units | degrees Celsius, degrees Fahrenheit |
| Computed values | dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy |
| Available atmospheric pressure units | hPa, kPa, mBar, mmHg, inHg, inH2O, PSI, oz/in2 |
| Accuracy and range of dew point temperature output - for more details see graphs in manual | ±1.5°C at ambient temperature T<25°C and RH>30% range -60 to +80°C |
| Range of humidity sensor temperature compensation | all temperature range |
| Temperature operating range of case with electronics | -30 to +80°C |
| IP protection | IP30 electronics, IP40 sensors |
| LAN connection | RJ-45 connector, 10Base-T or 100Base-TX |
| Communication protocols | WWW, ModbusTCP, SNMPv1, SOAP, XML |
| Alarm protocols | E-mail, SNMP Trap, Syslog |
| Configuration | T-Sensor, WWW configuration |
| Power | 9 to 30Vdc, maximum consumption 1W |
| Power connector | co-axial, diameter 5.5 x 2.1mm |
| Dimensions | 88.5 x 147.5 x 39.5mm (W x H x D), stem length 75mm |
| Weight | approximately 155g |
50 Ubi Ave 3, #02-06 Frontier, Singapore 408866.
+65-67477472
+65-67476768
sales-sg@mobicon.com.sg